MR TOOLS
UT586+ Digital RCD Tester
Electric Tools

UT586+ Digital RCD Tester

The UT586+ is an instrument crafted for verifying the functionality of single-phase and three-phase electrical leakage protection devices. It is equipped with capabilities to measure fault triggering times and the currents that initiate tripping. Adhering to the CAT III 600V safety rating, it finds broad application across residential, educational, power, manufacturing, metallurgical, and chemical sectors.

Available units in stock

Product Details

The UT586+ is an instrument crafted for verifying the functionality of single-phase and three-phase electrical leakage protection devices. It is equipped with capabilities to measure fault triggering times and the currents that initiate tripping. Adhering to the CAT III 600V safety rating, it finds broad application across residential, educational, power, manufacturing, metallurgical, and chemical sectors.

Features of UT586+ Digital RCD Tester

Certifications: CE/RoHS

1. RCD trip time/Current test

2. Multiple range & Auto range

3. Phase angle selection

4. Working voltage: 100V~440V

5. Voltage test: 30~480V

6. Over temp. detection

7. Backlight & APO & Low battery

8. CAT III 600V


FAQ

Q1: What is UT586+?

A1: UT586+ is a digital RCD tester, designed to test and verify single-phase and three-phase residual current protection devices. It can measure RCD trip current and trip time.

Q2: What is the safety rating of UT586+?

A2: It has a CAT III 600V safety rating.

Q3: What is the working voltage range and voltage measurement range?

A3: Working voltage: 100V~440V; Voltage test range: 30V~480V.

Q4: Does UT586+ support auto range?

A4: Yes, it supports multiple measuring ranges and auto range function.

Q5: What is the phase angle selection function for?

A5: It supports phase angle selection for RCD testing, to simulate different test conditions.

Q6: Does it have over-temperature protection?

A6: Yes, it is equipped with over temperature detection function to protect the instrument.

Q7: What convenient functions are built-in?

A7: It comes with LCD backlight, auto power off (APO) and low battery indication.

Q8: What certifications does UT586+ have?

A8: It has CE and RoHS certifications.

Q9: What industries can UT586+ be applied to?

A9: It is widely used in residential, educational, power, manufacturing, metallurgical and chemical industries for electrical safety inspection.


Specifications

Specification

Rate trigger current

Fault trigger time

Accuracy
(current)

Accuracy
(time)

RCD test function

X1/2

10/20/30/100/300/500mA/1000mA

0~2000mS @  0°/180°

 -10%~0%”

±0.6%rdg±4dgt

X1

10/20/30/100/300mA

0~2000mS @  0°/180°

0%~+10%

±0.6%rdg±4dgt

500mA/1000mA

0~200mS @  0°/180°

0%~+10%

±0.6%rdg±4dgt

X2

10/20/30/100/200/300/500mA

0~200mS @  0°/180°

0%~+10%

±0.6%rdg±4dgt

X5

10/20/30/100/200mA

0~200mS @  0°/180°

0%~+10%

±0.6%rdg±4dgt

AUTO

 10/20/30/100/300/500mA/1000mA

300ms @ 15 0°/180°

-10%~+10%

±0.6%rdg±4dgt

Manual

 10/20/30/100/300/500mA/1000mA

300ms @ 0°/180°

-10%~+10%

±0.6%rdg±4dgt

Working voltage

 50/60Hz

100V~440V
(Note: If > 450V, it will issue an alarm and stop the RCD test)

-15%~+10%

Voltage test

Voltage range

30~480V (Resolution: 1V)

45~65Hz

±3%rdg±3dgt

Voltage test

L-PE

yes, display the L-PE input voltage;
range: 30V~480V; No input and low voltage: “0V”;
if less than 30V: <30V; if  more than 4800v: >480V

Frequency

yes, display the L-PE input frequency;
when it is “volts”, press “VOLT/FREQ” key to switch “Voltage/Frequency”

Wiring check

If there is no wiring, an abnormal power supply, or no electricity flowing, the LCD will display “L-PE” and flash.

Phase angle selection

You can choose to initiate the test from the positive (0°) or the negative (180°) half-cycle. Press the “0°/180°” button to toggle phase.

Lock test

 With the power disconnected, press and hold the “0°/180°” button to activate the lock test function. Simply connect the test leads correctly to the test points, and the test will run automatically.

AUTO RAMP test

You can test the trip action current and action time simultaneously.

RCD test exceeds limit prompt

 When the trip action time exceeds the maximum test duration and trips.

Over-temperature detection

 If the internal components of the device become too hot, the LCD will display an over-temperature symbol, and the device will automatically disable RCD testing.

Backlight

Yes, can be turn on/off

Low battery indication

yes

Auto powwer off

After 5 minutes of no operation, it will automatically shut down.

Working environment

0℃~40℃

Storage environment

 -20℃~60℃

Power

8 * 1.5V AA

Polution level

2

Safety rating

IEC61010-031; IEC61557-1,6; CAT III 600V

General Features

Product color

Red + gray

Product weight

725g

Product dimension

161*117*68mm

Standard accessories

User manual 1pcs; Test lead 1 set(red/green); Alligator clips 2pcs(red/green); Test probe 2pcs(red/green); 1.5V AA * 8pcs; Test lead to EU plug 1pcs

Standard package

Carton box: 4pcs

Package dimension

585×380×335mm

Need More Information?

Our technical team is ready to help you find the right solution.