MR TOOLS
UT285C Three Phase Power Quality Analyzer
Electric Tools

UT285C Three Phase Power Quality Analyzer

The UNI-T UT285C is a professional three-phase power quality analyzer built for industrial power grid, photovoltaic and distribution cabinet testing. It supports real-time 4-channel voltage and current waveform display, and delivers True RMS measurement for voltage and current. It can test peak voltage & current, total harmonic distortion (THD), active/reactive/apparent power (per phase & cumulative value), transformer K factor, power factor, short-term voltage flicker (PST)

Available units in stock

Product Details

The UNI-T UT285C is a professional three-phase power quality analyzer built for industrial power grid, photovoltaic and distribution cabinet testing. It supports real-time 4-channel voltage and current waveform display, and delivers True RMS measurement for voltage and current. It can test peak voltage & current, total harmonic distortion (THD), active/reactive/apparent power (per phase & cumulative value), transformer K factor, power factor, short-term voltage flicker (PST), three-phase voltage and current unbalance. It comes with USB interface and matched PC software for data upload, analysis and report export, ideal for power maintenance engineers to diagnose power quality issues on site.

Key Features

● Waveform real-time display (4 channels voltage/current)

● True RMS values of voltages and currents

● Peak current and voltage values

● Total harmonic distortion (THD)

● Active, reactive, apparent power, by phase and cumulative

● Transformer K factor

● Power factors (PF) and displacement factors (DPF or COSΦ)

● Short-term voltage flicker (PST)

● Three phase unbalance(current and voltage)

● USB interface/PC software


FAQ

Q: What is UT285C used for?

A: It is a professional three-phase power quality analyzer, used for power grid, distribution cabinet and photovoltaic power quality inspection, to find harmonic, unbalance, flicker and power factor problems.

Q: How many channels does it support for waveform display?

A: It supports 4 channels of voltage and current real-time waveform display.

Q: Can it test harmonic distortion?

A: Yes, it can measure THD total harmonic distortion, and also calculate transformer K factor.

Q: Does it support data export?

A: Yes. It has a USB port, you can connect it to PC software to save, analyze and export test data.

Q: What power quality parameters can it measure?

A: It covers True RMS, peak value, THD, active/reactive/apparent power, PF, DPF, PST flicker, three-phase unbalance.


Specifications

Specifications

UT285C

True RMS phase-to-neutral voltage

1.0V~ 1000V

±(0.5%+5dgt)

True RMS phase-to phase voltage

1.0V~ 2000V

±(0.5%+5dgt)

DC voltage

1.0V~ 1000V

±(1.0%+5dgt)

True RMS current

008B current clamp: 10mA~10.0A(optional);
040B current clamp: 0.10A~100A(optional);
068B current clamp: 1.0A~1000A;
300F flexible current sensor (with Integrator) : 10A ~ 6000A(optional)

±(0.5%+5dgt)

Peak of phase-to-neutral voltage

1.0V~ 1414V

±(1.0%+5dgt)

Peak of phase-to-phase voltage

1.0V ~ 2828V

±(1.0%+5dgt)

Current peak

10mA ~ 6000A(optional)

±(1.0%+5dgt)

Active power

0.000W~ 9999.9kW

±(1%+3dgt)

Cosφ≥0.8

±(1.5%+10dgt)

0.2≤Cosφ<0.8

Reactive power, inductive or capacitive

0.000RVA~ 9999.9kVAR

±(1%+3dgt)

Sinφ≥0.5

±(1.5%+10dgt)

0.2≤Sinφ<0.5

Apparent power

0.000VA~ 9999.9kVA

±(1%+3dgt)

Power factor

-1.000~ 1.000

±(1.5%+3dgt)

Cosφ≥0.5

±(1.5%+10dgt)

0.2≤Cosφ<0.5

Active energy

0.000Wh~ 9999.9MWh

±(1%+3dgt)

Cosφ≥0.8

±(1.5%+10dgt)

0.2≤Cosφ<0.8

Reactive energy, inductive or capacitive

0.000VARh~ 9999.9MVARh

±(1%+3dgt)

Sinφ≥0.5

±(1.5%+10dgt)

0.2≤Sinφ<0.5

Apparent energy

0.000VAh~ 9999.9MVAh

±(1%+3dgt)

Phase angle

-179°~ 180°

±(2°)

Tanφ

-32.76~ 32.76

φ:±(1°)

(VA>50VA)

Phase shift of power factor

-1.000~ 1.000

φ:±(1°)

(DPF)

Harmonic ratio

0.0%~ 99.9%

±(1%+5dgt)

(order 1 to 50) (Vrms>50V)

Harmonic angle

-179°~ 180°

±(3°) harmonics of order 1 to 25

(Vrms>50V)

±(10°) harmonics of order 26 to 50

Total harmonic ratio

0.0%~ 99.9%

±(1%+5dgt)

Distortion factor

0.0%~ 99.9%

±(1%+10dgt)

(DF or THD-R)<50

Transformer K factor

1.00~ 99.99

±(5%)

3 phases unbalance

0.0%~ 100%

±(1%)

Number of channels

4U/4I

Parameters of electricity

W, VA, Var, PF, DPF, cosφ, tanφ

Energy parameters

Wh, Varh, Vah

Harmonic

50

Total harmonic distortion

Order 0~50, each phase

Expert mode

Yes

Number of Transient records

150 sets

3 phases unbalance

Yes

Min/Max

Yes

Alarm

40 different types of parameter selections, 12,800 sets alarm logs

Peak

Yes

Phasor diagram display

Auto

Auto power off

Yes

Backlight

Yes

Menu language

English/Chinese

USB interface/PC software

Yes

General Characteristics

Power

9.6V rechargeable lithium-ion battery

Product color

Red and grey

Product net weight

Instrument: 1.6kg, current clamp: 510g x 4

Product size

240mm × 170mm × 68 mm

Standard accessories

1pc carry cloth bag, (yellow, green, red, blue, black total 5pcs test lead), 4pcs alligator clip, 1pc power adapter, 4pcs 1000A current clamp

Standard individual packing

Inner carton

Standard quantity per carton

1pc

Standard carton measurement

440 x 320 x 330mm

Standard carton gross weight

6.4kg