UT513C 5kV Insulation Resistance Testers
UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.
Product Details
UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.
Features of UT513B/UT513C 5kV Insulation Resistance Testers
Certificates: CE, UKCA
● Output voltage: Up to 5kV
● PI & DAR measurement
● Automatic leakage current display
● Stepping voltage: 10% of the range
● Comparison function
● Timer measurement
● Data storage: 999 sets
● PC software analysis: via USB cable
● Automatic discharge
● High voltage output alarm function
● Rechargeable lithium battery 14.8V, 5200mAh
● Overvoltage category: CAT IV 600V
FAQ
Q1: What is the maximum output voltage of UT513B / UT513C?
A1: Max output voltage is up to 5kV, with 250V/500V/1000V/2500V/5000V selectable voltage gears. The voltage can be adjusted in 10% stepping of the full range.
Q2: What are PI and DAR functions used for?
A2: PI (Polarization Index) and DAR (Dielectric Absorption Ratio) are for insulation aging evaluation, widely used for transformers, motors and power cables.
Q3: What safety standard does this meter comply with?
A3: It is CAT IV 600V overvoltage category, with CE and UKCA certificates. It has high voltage output alarm and automatic discharge function for safe operation.
Q4: How many test data can be stored?
A4: It supports storage of up to 999 sets of measurement data. Data can be uploaded to PC via USB cable for analysis with supporting PC software.
Q5: What is the battery specification?
A5: Built-in rechargeable 14.8V, 5200mAh lithium battery, suitable for long-time field testing.
Q6: What is the difference between UT513B and UT513C?
A6: UT513B measuring range up to 2TΩ; UT513C up to 5TΩ, additionally supports capacitance measurement and Bluetooth APP function.
Q7: Does it have timer measurement and comparison function?
A7: Yes. It supports timer measurement, resistance comparison judgment, and automatic leakage current display.
Q8: What applications are suitable for UT513B / UT513C?
A8: Ideal for power maintenance, transformer, generator, high-voltage motor, cable insulation testing in power plants, substations and industrial electrical systems.
Specifications of UT513B/UT513C 5kV Insulation Resistance Testers
Rated voltage | UT513B | UT513C |
250V | <0.25MΩ: reference only | <0.25MΩ: reference only |
0.25MΩ~2.49GΩ: ±5%+5) | 0.25MΩ~4.99GΩ: ±(5%+5) | |
2.50GΩ~24.9GΩ: ±(10%+10) | 5.00GΩ~49.9GΩ: ±(10%+10) | |
25.0GΩ~100GΩ: reference only | 50.0GΩ~250GΩ: reference only | |
500V | <0.50MΩ: reference only | <0.50MΩ: reference only |
0.50MΩ~4.99GΩ: ±(5%+5) | 0.50MΩ~4.99GΩ: ±(5%+5) | |
5.00GΩ~49.9GΩ: ±(10%+10) | 5.00GΩ~99.9GΩ: ±(10%+10) | |
50.0GΩ~200GΩ: reference only | 100GΩ~500GΩ: reference only | |
1000V | <1.00MΩ: reference only | <1.00MΩ: reference only |
1.00MΩ~9.99GΩ: ±(5%+5) | 1.00MΩ~9.99GΩ: ±(5%+5) | |
10.0GΩ~99.9GΩ: ±(10%+10) | 10.0GΩ~199GΩ: ±(10%+10) | |
100GΩ~400GΩ: reference only | 200GΩ~1.00TΩ: reference only | |
2500V | <2.50MΩ: reference only | <2.50MΩ: reference only |
2.50MΩ~24.9GΩ: ±(5%+5) | 2.50MΩ~24.9GΩ: ±(5%+5) | |
25.0GΩ~249GΩ: ±(15%+10) | 25.0GΩ~499GΩ: ±(15%+10) | |
250GΩ~1.00TΩ: reference only | 500GΩ~2.50TΩ: reference only | |
5000V | <5.00MΩ: reference only | <5.00MΩ: reference only |
5.00MΩ~49.9GΩ: ±(5%+5) | 5.00MΩ~49.9GΩ: ±(5%+5) | |
50.0GΩ~499GΩ: ±(15%+20) | 50.0GΩ~999GΩ: ±(15%+20) | |
500GΩ~2.00TΩ: reference only | 1.00TΩ~5.00TΩ: reference only | |
Capacitance test | NA | 0.01uF~15.0uF |
Output voltage | stepping voltage range | Step by 10% of each range each time, and adjust the voltage range to 50%~120% of each range |
250V | 250V, 275V, 300V | |
500V | 250V, 300V, 350V, 400V, 450V, 500V, 550V, 600V | |
1000V | 500V, 600V, 700V, 800V, 900V, 1000V, 1100V, 1200V | |
2500V | 1250V, 1500V, 1750V, 2000V, 2250V, 2500V, 2750V, 3000V | |
5000V | 2500V, 3000V, 3500V, 4000V, 4500V, 5000V | |
DC voltage | 30~1000VDC: ±(3%+5) | |
AC voltage | 30~750VAC(50Hz/60Hz): ±(3%+5) | |
Current | 0.01nA~3.5mA | 0.01nA~5.0mA |
Short-circuit current | about 3.5mA | about 5.0mA |
Main features | ||
PI test | ✔ | ✔ |
DAR test | ✔ | ✔ |
Timing measurement | ✔ | ✔ |
Resistance Comparison | ✔ | ✔ |
Voltage step | ✔ | ✔ |
Voltage monitoring (of an external object) | Monitor the voltage of the measured object and the discharge state after testing. If the voltage is higher than 36V, it is forbidden to test to protect the tester and the operator | |
Timer testing | Record testing time automatically. Timing range: 0s~99m and 59s | |
Data storage | 999 set | 999 set |
USB interface (data transmission) | ✔ | ✔ |
Bluetooth APP | N/A | ✔ |
Low Battery indication | ✔ | ✔ |
Auto power off | Around 15 minutes | Around 15 minutes |
Overvoltage category | CAT Ⅳ 600V | CAT Ⅳ 600V |
Certificates | CE & UKCA | CE & UKCA |
Need More Information?