MR TOOLS
Product Launch

UT276B/UT276C Earth Clamp Meters

November 18, 2026MR TOOLS Team

UT276B/UT276C Earth Clamp Meters

UT276B and UT276C earth clamp meters use mutual induction to measure ground resistance without driving auxiliary ground rods. Choose between 1200Ω/20A (B) or 1800Ω/40A (C) ranges, featuring a 44.5mm jaw, 500-set storage, and Bluetooth connectivity for telecom, power, and facility grounding inspections.

The UT27X Series Earth Clamp Meter is a device for measuring ground resistance, featuring easy operation, portability, high accuracy, and strong anti-interference capability; it is widely used in telecommunications, power, equipment rooms, and other fields.

Features

Certifications:  CE/ETL/RoHS

  1. Resistance measurement:

    • UT276B: 0.010~ 1200Ω ;

    • UT276C: 0.010~1800Ω

  2. AC Current measurement:

    • UT276B: 0.200mA~20.0A

    • UT276C: 0.200mA~40.0A

  3. Earth resistance accuracy:±(1%+0.01Ω)

4. Max measurable diameter:φ 44 mm (busbar or cable)

5. Data storage: 500 sets

6. Bluetooth data communication

7. 4-digit LCD

8. Self-calibration when power is on

9. IEC 61010-1; IEC61010-2-032; IEC61326

10. Certificates: CE/ETL/RoHS


What's New in the UT276B/UT276C?

The UT276B and UT276C are industrial earth clamp meters designed for fast, safe grounding system checks. Unlike traditional fall-of-potential testing, these meters clamp around the grounding conductor and measure loop resistance through mutual induction—no need to disconnect the ground lead or drive auxiliary electrodes .

1. Two Range Options

UT276B: Earth resistance 0.010–1200Ω, AC current 0.200mA–20.0A

UT276C: Earth resistance 0.010–1800Ω, AC current 0.200mA–40.0A

Both models offer a minimum resistance resolution of 0.001Ω and AC current resolution down to 0.01mA, making them suitable for both grounding resistance checks and leakage current detection .

2. 44.5mm Jaw Opening

The clamp jaw opens up to 44.5mm, fitting most grounding busbars and thick cables found in telecom towers, distribution cabinets, and industrial grounding grids .

3. On-Site Efficiency

500-set data storage with review and delete functions

Bluetooth communication for wireless data transfer to mobile devices

4-digit LCD with backlight for clear readings in low-light environments

Self-calibration on power-on and a test ring for quick verification before use

4. Built for Field Work

With strong anti-interference capability, shockproof/dustproof construction, and a CAT IV 600V safety rating, the UT276B/C is ready for demanding outdoor and industrial environments .


Key Applications

Telecom Towers & Base Stations: Ground resistance checks without climbing or disconnecting down-leads

Power Distribution & Substations: Verify grounding grids and lightning protection systems

Equipment Rooms & Data Centers: Ensure proper grounding for sensitive electronics

Oil Fields & Gas Stations: Grounding verification in hazardous areas

Factory Grounding Networks & Lightning Rods: Routine maintenance and fault detection


Specifications

Functional

UT276B

UT276C

Earth Resistance
(Auto range)

Range

Resolution

Accuracy

Range

Resolution

Accuracy

0.010Ω-0.099Ω

0.001Ω

±(1%+0.02Ω)

0.010Ω-0.099Ω

0.001Ω

±(1%+0.02Ω)

0.1Ω-0.99Ω

0.01Ω

±(1%+0.05Ω)

0.1Ω-0.99Ω

0.01Ω

±(1%+0.05Ω)

1.0Ω-49.9Ω

0.1Ω

±(1%+0.5Ω)

1.0Ω-49.9Ω

0.1Ω

±(1%+0.5Ω)

50.0Ω-99.5Ω

0.5Ω

±(1.5%+0.5Ω)

50.0Ω-99.5Ω

0.5Ω

±(1.5%+0.5Ω)

100Ω-199Ω

1Ω

±(2.5%+1Ω)

100Ω-199Ω

1Ω

±(2.5%+1Ω)

200Ω-395Ω

5Ω

±(5%+5Ω)

200Ω-395Ω

5Ω

±(5%+5Ω)

400-590Ω

10Ω

±(10%+10Ω)

400-590Ω

10Ω

±(10%+10Ω)

600Ω-880Ω

20Ω

±(20%+20Ω)

600Ω-880Ω

20Ω

±(20%+20Ω)

900Ω-1.20KΩ

0.03KΩ

±(25%+0.03KΩ)

900Ω-1.80KΩ

0.03KΩ

±(25%+0.03KΩ)

AC Current
(Auto range/
50Hz/60Hz)

0.10mA -9.99mA

0.01mA

±(2.0%+1mA)

0.10mA -9.99mA

0.01mA

±(2.0%+1mA)

10.0mA -99.9mA

0.1mA

±(2.0%+5.0mA)

10.0mA -99.9mA

0.1mA

±(2.0%+5.0mA)

100mA -999mA

1mA

±(2.0%+10mA)

100mA -999mA

1mA

±(2.0%+10mA)

1.00A-9.99A

0.01A

±(2.0%+0.1A)

1.00A-9.99A

0.01A

±(2.0%+0.1A)

10.0A-20.0A

0.1A

±(2.0%+0.3A)

10.0A-40.0A

0.1A

±(2.0%+0.3A)

Testing method

Mutual inductance method

Mutual inductance method

Functional

  1. Earth resistance test;

  2. Loop resistance test;

  3. AC test (leakage current)

  1. Earth resistance test;

  2. Loop resistance test;

  3. AC test (leakage current)

Max measurable
conductor dia.

Max Ф44mm

Max Ф44mm

Display

4-digit LCD

4-digit LCD

Sampling rate

2 time/s

2 time/s

Data storage

500 set

500 set

Over range indication

YES

YES

Data recall

YES

YES

Bluetooth

YES

YES

APO

Around 10 minutes without operation

Around 10 minutes without operation

Insulation Resistance

50MΩ/1000V

50MΩ/1000V

Power consumption

Around 55mA(max:150mA)

Around 55mA(max:150mA)

Working temp.

 -10ºC ~50ºC relative humidity below 85%, no condensation.

Storage temp.

-20ºC ~ 60ºC relative humidity below 85%, no condensation.

IP Rating

IP40

IP40

Safety regulation grade

IEC 61010-1 :2001(CATIV 600V; Pollution degree: 2)
IEC 61010-2-032: 2002
IEC 61326 :2000(EMC standard)

IEC 61010-1 :2001(CATIV 600V;Pollution degree: 2)
IEC 61010-2-032: 2002
IEC 61326 :2000(EMC standard)

Category rating

CAT IV 600V

CAT IV 600V

Product size

270mm×94mm×58mm

270mm×94mm×58mm

General Characteristics

Color

Red+ gray

Weight(with batteries)

1.1kg

Product size

284mm*94mm*61.5mm

Standard Accessories

  1. Bare product:1pcs

  2. QSG: 1pcs

  3. Documents download operation guide: 1pcs

  4. Standard resistance calibration ring: 1pcs

  5. 1.5V LR6 AA batteries*4 pcs

  6. Tool box:1pcs

Standard packaging

Carton+hard carrying case

Standard packaging Qty

2pcs/carton

Standard packaging size

 360×230×290mm

Standard packaging gross weight